Custom Network and Electrical Cabinet Housing

Custom network and electrical cabinet housings manufactured for equipment builders that need a tailored metal shell, secure mounting space and practical cable access. Cabinet size, door layout, internal supports and finish follow customer-approved drawings and component requirements.

  • Материал :

    Carbon steel / zinc-coated steel / stainless steel / aluminum, as specified
  • Общий класс :

    SPCC or DC01 sheet; SGCC zinc-coated sheet; 304 stainless steel; 5052 aluminum
  • Толщина :

    According to Drawing
  • Размер :

    Custom to Drawing
  • Отделка поверхности :

    Powder coating / brushed finish / passivation / anodizing, by material and project
  • Производственный процесс :

    Laser Cutting / CNC Punching / Bending / Welding / Finishing / Assembly
  • Панель адаптера :

    Custom
  • Монтаж соединительного лотка :

    Custom
  • Кабельный ввод :

    Cable-entry plates / cut-outs / routing features
  • Объем поставок :

    Metalwork Only / Hardware Installation / Component Assembly / Wiring Integration
  • Основа сборки :

    Approved Drawing / BOM / Wiring Diagram / Sample
  • Приложение :

    Network and communication equipment · Electrical distribution and control equipment · Industrial automation cabinets · OEM equipment assemblies
  • Overview

    Glass door network cabinet application

    This housing is built around the internal equipment envelope, service access and mounting interfaces rather than a fixed stock size. Coordinating rack positions, cable-entry zones, fastener locations and removable panels before fabrication helps reduce fit-up changes during final equipment assembly.

    Applications: Network and communication equipment · Electrical distribution and control equipment · Industrial automation cabinets · OEM equipment assemblies

    Recommended Materials

    • Carbon and Zinc-Coated Steel

      Carbon and Zinc-Coated Steel

      SPCC or DC01 supports formed panels and doors; zinc-coated sheet is an option where the design specifies a coated substrate. Coating repairs may be needed at affected cut or weld areas.
    • Stainless steel 304

      Stainless Steel

      304 is an option for projects requiring exposed stainless surfaces or more corrosion resistance. The specified environment determines whether other grades are needed.
    • Aluminum

      5052 can be considered for lighter formed panels and cabinet components; the approved design determines joining and grounding details.

     

    Read more materials

     

    Customization Options

    Cabinet Customization Options

    • Cabinet Envelope & Layout

      Cabinet Envelope & Layout

      Customize width, depth, door swing, removable panels and equipment clearances.
    • Mounting & Cable Interfaces

      Mounting & Cable Interfaces

      Add backplates, rail supports, gland-plate locations and cut-outs matching the approved BOM.
    • Finish & Assembly Scope

      Finish & Assembly Scope

      Choose material-specific finishes, hardware installation and project-defined mechanical assembly.

    Key Design Considerations

    • Equipment Fit

      Equipment Fit

      Reserve enough clearance for installed modules, connectors, bends in cables and service operations.
    • Cable Entry Positions

      Cable Entry Positions

      Align holes, gland plates and cable routes to the customer wiring layout.
    • Door & Panel Alignment

      Door & Panel Alignment

      Control panel flatness, hinge locations and latch engagement for reliable access.
    • Thermal & Environmental Requirements

      Thermal & Environmental Requirements

      Ventilation or sealing features must follow the equipment heat load and specified installation conditions.

    Manufacturing Process

    We provide an integrated manufacturing process covering precision sheet metal fabrication, surface finishing, hardware and component installation, mechanical assembly, internal wiring and final inspection.

    Additional operations, including machining, deburring, grinding and tapping, can be incorporated according to the approved drawings and project requirements. Products can be supplied as empty enclosures, partially assembled units or wired cabinet assemblies based on customer-approved BOMs and wiring diagrams.

     

    OEM Manufacturing Support 

    Prototype production and DFM review are available for new projects before volume manufacturing. Learn more on our Capabilities page

     

    Prototype production and DFM review are available for new projects before volume manufacturing. Learn more on our Capabilities page

    After-Sales Support

    We support quality feedback, replacement parts, repeat production and approved design updates for ongoing OEM projects according to the agreed project scope.

    FAQ

     
    Can you build the cabinet around our network equipment layout?

    Yes. Supply the approved enclosure drawing, device layout and mounting interfaces so the cabinet can be fabricated to your specifications.

    Can you add door hardware and internal mounting plates?

    Hinges, locks, mounting plates and other hardware can be installed when included in the approved specification and scope.

    Do you supply a fully certified electrical control system?

    The core offer is metal cabinet manufacturing and agreed assembly. Electrical design, system testing and complete equipment certification are not implied and must be confirmed separately.

    Can we approve a sample before volume orders?

    A prototype or sample can be discussed to check panel fit, mounting positions and the finish before repeat production.

     

     

оставить сообщение
Если вас заинтересовала наша продукция и вы хотите узнать больше подробностей, пожалуйста, оставьте сообщение здесь, мы ответим вам как можно скорее.
оставить сообщение
Если вас заинтересовала наша продукция и вы хотите узнать больше подробностей, пожалуйста, оставьте сообщение здесь, мы ответим вам как можно скорее.